Roofing at a glance
| Material | Weight per SQ | Lowest typical pitch | Typical service life |
|---|---|---|---|
| Exposed-fastener metal panels | About 50–100 lb, by gauge | ½:12 to 3:12, by profile | 30–40+ years |
| Standing seam | About 80–150 lb, by gauge | ¼:12 to 3:12, by system | 40+ years |
| Architectural shingles | About 220–350 lb | 4:12 (2:12 with double underlayment) | 25–30+ years |
| Concrete tile | About 900–1,200 lb | 2½:12 | 50+ years |
| Clay tile | About 600–1,800 lb, by profile | 2½:12 | 50–100+ years |
| Natural slate | About 800–1,500 lb, by thickness | 4:12, traditional install | 75–100+ years (S1 grade) |
| Single-ply membrane | Light | ¼:12 | Varies by membrane and thickness |
Metal
- Gauges. 29, 26 and 24 for most roofing and siding; 22 for heavy commercial; 16 to 12 for framing.
- Panel coverage. 36″ for R-panel and ag rib, 24″ for 5V, 12″ to 18″ for most standing seam.
- Paint. SMP for everyday use, PVDF for the longest color life.
Walls and structure
- Purlins and girts. C and Z, 4″ to 12″ deep, 16 to 12 gauge.
- Hat channel. ⅞″ to 1½″, 25 to 16 gauge.
- Insulation. Polyiso about R-5.6 to R-6 per inch; EPS and XPS about R-3.6 to R-5 per inch.
Finish and install
- Underlayment. Synthetic about 4–10 SQ per roll; self-adhered about 2 SQ.
- Fasteners. About 75–80 screws per SQ for exposed-fastener panels.
- Trim. Standard pieces usually about 10′; laps often 2″ to 6″.
Typical ranges only. The manufacturer's data and local code govern each product.